S5735S-L48P4S-A1 Overview
Built on next-generation, high-performance hardware and powered by
Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L
switches feature flexible Ethernet networking, diversified security
control, and support for multiple Layer 3 routing protocols — providing
higher performance and more powerful service processing capabilities
for networks.
S5735S-L48P4S-A1 Specification
Item | Specification |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 3.23 kg (7.12 lb) |
Weight with packaging [kg(lb)] | 4.28 kg (9.44 lb) |
Typical power consumption [W] | 58.7 W |
Typical heat dissipation [BTU/hour] | 200.29 BTU/hour |
Maximum power consumption [W] | · Not providing the PoE function: 76.1 W · 100% PoE loads: 456.1 W (PoE: 380 W) |
Maximum heat dissipation [BTU/hour] | · Not providing the PoE function: 259.66 · 100% PoE loads: 155.26 |
MTBF [year] | 44.9 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 50 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 38.2 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 2 |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: · The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year. · The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year. · The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage emperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | AC built-in |
Rated input voltage [V] | · AC input: 100 V AC to 240 V AC, 50/60 Hz · High-Voltage DC input: 240 V DC |
Input voltage range [V] | · AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz · High-Voltage DC input: 190 V DC to 290 V DC |
Maximum input current [A] | 6 A |
Memory | 512 MB |
Flash memory | 512 MB |
Console port | RJ45 |
Eth Management port | Not supported |
USB | Supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | ±6 kV in differential mode, ±6 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Supported |
Certification | EMC certification Safety certification Manufacturing certification |
Product Details
Figure 1 shows the appearance of S5735S-L48P4S-A1 .
1 | Forty-eight 10/100/1000BASE-T PoE+ ports | 2 | Four 1000BASE-X ports |
3 | One console port | 4 | One USB port |
5 | One PNP button NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 6 | Ground screw NOTE: It is used with a ground cable. |
7 | Jack for AC power cable locking strap NOTE: The AC power cable locking strap is not delivered with the switch. | 8 | AC socket NOTE: It is used with an AC power cabe . |
The Accessories
Table 2 shows the recommended transceivers, card and power module.
Model | Description |
Huawei Optical Transceiver OMXD30000, SFP+, 10G, Multi-mode Module (850nm, 0.3km, LC) | |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC) | |
OMXD30009 | Transceiver , QSFP+ , 1310nm , 41.25Gbps , -7dBm , 2.3dBm , -11.5dBm, LC, SMF, 10 |
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm,0.5km, LC) |
Get More Information