Huawei S5731-S Series Switch S5731-S24T4X
Huawei S5731-S Series Switch S5731-S24T4X
  • Huawei S5731-S Series Switch S5731-S24T4X
  • Huawei S5731-S Series Switch S5731-S24T4X

S5731-S24T4X

The Huawei CloudEngine S5731-S series switches were developed based on next-generation high-performing hardware and the Huawei Versatile Routing Platform (VRP). The CloudEngine S5731-S supports simplified operations and maintenance (O&M), intelligent stack (iStack), flexible Ethernet networking. It also provides enhanced Layer 3 features and mature IPv6 features. The CloudEngine S5731-S can be used in various scenarios. For example, it can be used as an access or aggregation switch on a campus network or as an access switch for Metropolitan Area Network.

Description

S5731-S24T4X Overview


The Huawei CloudEngine S5731-S series switches were developed based on 

next-generation high-performing hardware and the Huawei Versatile Routing 

Platform (VRP). The CloudEngine S5731-S supports simplified operations and 

maintenance (O&M), intelligent stack (iStack), flexible Ethernet networking. 

It also provides enhanced Layer 3 features and mature IPv6 features. 

The CloudEngine S5731-S can be used in various scenarios. For example, 

it can be used as an access or aggregation switch on a campus network or as 

an access switch for Metropolitan Area Network.


S5731-S24T4X Specification

 

S5731-S24T4X Specification

Fixed port

24 x 10/100/1000Base-T ports, 4 x     10GE   SFP+ ports

Dimensions     (W   x D x H)

442 mm x 420 mm x 43.6 mm

Chassis     height

1 U

Chassis     weight   

(including packaging)

8.4 kg

Power  supply   type
     
     

• 150 W AC (pluggable)

• 600 W AC (pluggable)

• 1000 W DC (pluggable)

Rated  voltage   range
     
     

• AC input (150 W AC ): 100 V     AC   to 240 V AC, 50/60 Hz

• AC input (600 W AC ): 100 V     AC   to 240 V AC, 50/60 Hz

• DC input (1000 W DC): -48     VDC   to -60 V DC

Maximum   voltage range


     
     

• AC input   (150 W AC ): 90 V   AC   to 264 V AC, 47 Hz to 63 Hz

• AC input   (600 W AC ): 90 V   AC   to 290 V AC, 45 Hz to 65 Hz

• High-voltage   DC input (600 W     AC): 190 V DC to 290 V DC 

  (meeting 240   V high-voltage DC   certification)

• DC input   (1000 W DC): -38.4   V   DC to -72V DC

Maximum  power consumption

114 W

Noise
     
     

• Under normal temperature     (sound   power): 57.5dB (A)

• Under high temperature     (sound   power): 70.9dB (A)

• Under normal temperature     (sound   pressure): 47.5dB (A)

Operating       temperature
     
     

• 0-1800 m   altitude: -5°C to     +45°C

• 1800-5000 m   altitude: The     operating temperature reduces 

   by   1ºC every time the altitude   increases   by 220 m.

Storage       temperature

-40 to +70

Relative       humidity

5% to 95% (non-condensing)

Surge  protection specification

 (service port)

Common mode: ±6 kV

Surge  protection specification 

(power port)

 

• AC power port: ±6 kV   in     differential mode, ±6 kV in common mode

• DC power port: ±2 kV   in     differential mode, ±4 kV in common mode

Heat       dissipation

 

Air cooling heat   dissipation,     intelligent speed adjustment, 

and pluggable   fans

Service       Features

MAC       address table

IEEE 802.1d standards compliance

32K MAC address entries

MAC address learning and aging

Static, dynamic, and blackhole MAC       address entries

Packet filtering based on source     MAC   addresses

VLAN

4094 VLANs

Guest VLAN and   voice VLAN

GVRP

MUX VLAN

VLAN assignment   based on MAC     addresses, protocols, 

IP subnets,   policies, and ports

VLAN mapping

Ethernet     loop   protection

 

RRPP ring topology   and RRPP     multi-instance

Smart Link tree   topology and Smart     Link multi-instance, 

providing   millisecond-level protection switching

SEP

ERPS (G.8032)

BFD for OSPF, BFD   for IS-IS, BFD   for   VRRP, and BFD for PIM

STP (IEEE 802.1d),   RSTP (IEEE   802.1w),   and MSTP (IEEE 802.1s)

BPDU protection,   root protection,   and   loop protection

IP routing

Static routes, RIP   v1/2, RIPng,   OSPF,   OSPFv3, IS-IS, IS-ISv6, BGP, 

BGP4+, ECMP,   routing policy

Up to 16K FIBv4   entries

Up to 8K FIBv4   entries

Interoperability

VLAN-Based Spanning Tree (VBST),       working with PVST, PVST+, and RPVST

Link-type Negotiation Protocol     (LNP),   similar to DTP

VLAN Central Management Protocol       (VCMP), similar to VTP

IPv6     features

Up to 8K ND entries

PMTU

IPv6 Ping, IPv6   Tracert, and IPv6     Telnet

ACLs based on   source IPv6   addresses,   destination IPv6 addresses, 

Layer 4 ports, or   protocol   types

Multicast Listener   Discovery   snooping   (MLDv1/v2)

IPv6 addresses   configured for     sub-interfaces, VRRP6, DHCPv6, and L3VPN

Multicast

IGMP v1/v2/v3 snooping and IGMP     fast   leave

Multicast forwarding in a VLAN and       multicast replication between VLANs

Multicast load balancing among     member   ports of a trunk

Controllable multicast

Port-based multicast traffic       statistics

IGMP v1/v2/v3, PIM-SM, PIM-DM, and       PIM-SSM

MSDP

MVPN

QoS/ACL

Rate limiting in   the inbound and     outbound directions of a port

Packet redirection

Port-based traffic   policing and     two-rate three-color CAR

Eight queues per   port

DRR, SP and DRR+SP   queue scheduling     algorithms

WRED

Re-marking of the   802.1p and DSCP     fields of packets

Packet filtering at   Layer 2 to   Layer   4, filtering out invalid   frames based 

on the source MAC     address,   destination MAC address, source IP address, 

destination IP     address, TCP/UDP   port number, protocol type, and VLAN ID

Queue-based rate   limiting and   shaping   on ports

Security

Hierarchical user   management and     password protection

DoS attack defense,   ARP attack     defense, and ICMP attack defense

Binding of the IP   address, MAC     address, port number, and VLAN ID

Port isolation,   port security, and     sticky MAC

MAC Forced   Forwarding (MFF)

Blackhole MAC   address entries

Limit on the number   of learned MAC     addresses

IEEE 802.1x   authentication and   limit   on the number of users on a port

AAA authentication,   RADIUS     authentication, and HWTACACS authentication

NAC

SSH V2.0

HTTPS

CPU protection

Blacklist and   whitelist

Attack source   tracing and   punishment   for IPv6 packets such as ND, 

DHCPv6, and MLD   packets

Secure Boot

IPSec

ECA

Deception

Reliability

LACP

E-trunk

Ethernet OAM (IEEE 802.3ah and   IEEE     802.1ag)

ITU-Y.1731

DLDP

LLDP

BFD for BGP, BFD for IS-IS, BFD   for     OSPF, BFD for static route

VXLAN*

VXLAN L2 and L3 gateways

Centralized and distributed   gateway

BGP-EVPN

Configured through the NETCONF       protocol

Super     Virtual   Fabric (SVF)

 

A two-layer client   architecture is     supported.

IGMP snooping can   be enabled on   access   switches (ASs) and the 

maximum number of   access users on a port   can be   configured.

ASs can be   independently   configured.   Services that are not 

supported by   templates can be   configured on the   parent.

Third-party devices   are allowed     between SVF parent and clients.

Working as an SVF   client that is     plug-and-play with zero configuration

iPCA

Directly coloring   service packets   to   collect real-time statistics on the 

number of lost   packets and   packet loss   ratio

Collection of   statistics on the   number   of lost packets and packet loss 

ratio at network   and device   levels

TWAMP

Two-way IP link   performance     measurement

Measurement on   two-way packet   delay,   one-way packet loss rate, 

and one-way packet   jitter

Management  and   maintenance

 

iStack, with up to 9 member     switches   in a stack

SNMP v1/v2c/v3

RMON

Smart Application Control (SAC)

Web-based NMS

System logs and alarms of   different     levels

GVRP

MUX VLAN

NetStream

Intelligent O&M

*CloudEngine   S5731-S series   switches   require the VXLAN license or N1   advanced  software  package to   support   the   

VXLAN feature.

 

Product Details

Figure 1 shows the front panel of S5731-S24T4X.

download (2).png

 

1

Twenty-four   10/100/1000BASE-T ports

2

Four 10GE SFP+   optical ports

3

One console   port

4

One ETH   management port

5

One USB port

6

One PNP button

NOTICE:

To restore the   factory settings and reset the switch, 

 hold   down the button for at   least 6 seconds.

To reset the   switch, press the button.

Resetting the   switch will cause service interruption. Exercise   

caution when you   press the PNP button.

7

Ground screw

NOTE:

It is used   with a ground cable.

8

Power module   slot 1

NOTE:

Applicable   power module:

 ·        PAC150S12-R (150 W AC Power Module)

 ·        PDC180S12-CR (180 W DC Power Module)

 ·        PAC600S12-CB (600 W AC Power Module)

 ·        PAC600S12-DB (600 W AC Power Module)

 ·        PAC600S12-EB (600 W AC Power Module)



9

Power module   slot 2

NOTE:

Applicable   power module:

 ·        PAC150S12-R (150 W AC Power Module)

 ·        PDC180S12-CR (180 W DC Power Module)

 ·        PAC600S12-CB (600 W AC Power Module)

 ·        PAC600S12-DB (600 W AC Power Module)

 ·        PAC600S12-EB (600 W AC Power Module)



-

-

 

Applicable Modules

Table 3 shows the recommended modules.

Model

Description

PAC600S12-CB

600W AC Power Module(Back to Front, Power   panel side exhaust)

eSFP-GE-SX-MM850

Optical Transceiver,eSFP,GE,Multi-mode   Module(850nm,0.55km,LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver,eSFP,GE,Single-mode   Module(1550nm,40km,LC)

SFP-GE-LX-SM1310

Optical Transceiver,eSFP,GE,Single-mode   Module(1310nm,10km,LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver,eSFP,GE,Single-mode   Module(1310nm,40km,LC)

S-SFP-GE-LH80-SM1550

Optical Transceiver,eSFP,GE,Single-mode   Module(1550nm,80km,LC)

SFP-GE-ZBXU1

Optical Transceiver,eSFP,GE,BiDi   Single-mode   Module(1490nm(Tx)/1570nm(Rx),80km,LC)

SFP-GE-LX-SM1490-BIDI

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1490/RX1310,10km,LC)

SFP-GE-ZBXD1

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(1570nm(Tx)/1490nm(Rx),80km,LC)

LE2MGSC40DE0

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1310/RX1490,40km,LC)

SFP-GE-LX-SM1310-BIDI

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1310/RX1490,10km,LC)

LE2MGSC40DE0

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1490/RX1310,40km,LC)

SFP-GE-BXU1-SC

1000Base,BIDI Optical   Transceiver,SFP,GE,Single-mode   Module

(TX1490nm/RX1310nm,10km,SC)

SFP-10G-ER-SM1270-BIDI

Optical Transceiver,SFP+,10G,BIDI   Single-mode Module

(TX   1270nm/RX 1330nm,40km,LC)

SFP-10G-BXU1

10GBase,BIDI Optical   Transceiver,SFP+,10G,Single-mode   Module

(TX1270nm/RX1330nm,10km,LC)

SFP-10G-ER-1310

Optical Transceiver,SFP+,10G,Single-mode     Module(1310nm,40km,LC)

SFP-10G-BXD1

10GBase,BIDI Optical   Transceiver,SFP+,10G,Single-mode   Module

(TX1330nm/RX1270nm,10km,LC)

SFP-10G-ZR

10GBase-ZR Optical   Transceiver,SFP+,10G,Single-mode   Module(1550nm,80km,LC)

OSX040N01

Optical Transceiver,SFP+,10G,Single-mode     Module(1550nm,40km,LC)

 

Get More Information

Do you have any question about the Huawei S5731-S24T4X?

Contact us now via Live Chat or andy@ryderwell.com.




send inquiry to us

Related Product

Chat with us