Huawei S5731-H Series Switch S5731-H24T4XC
Huawei S5731-H Series Switch S5731-H24T4XC
Huawei S5731-H Series Switch S5731-H24T4XC
Huawei S5731-H Series Switch S5731-H24T4XC
Huawei S5731-H Series Switch S5731-H24T4XC
  • Huawei S5731-H Series Switch S5731-H24T4XC
  • Huawei S5731-H Series Switch S5731-H24T4XC
  • Huawei S5731-H Series Switch S5731-H24T4XC
  • Huawei S5731-H Series Switch S5731-H24T4XC
  • Huawei S5731-H Series Switch S5731-H24T4XC

S5731-H24T4XC

Huawei S5731-H24T4XC is Huawei S5731-HSeries Switch with 24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 1*expansion slot, without power module.


The CloudEngine S5731-H series switches are the next-generation intelligent gigabit fixed switches developed by Huawei. The CloudEngine S5731-H builds on Huawei's unified Versatile Routing Platform (VRP) and boasts various IDN features.

Description

S5731-H24T4XC Overview


The CloudEngine S5731-H series switches are the next-generation intelligent gigabit 

fixed switches developed by Huawei. The CloudEngine S5731-H builds on Huawei's 

unified Versatile Routing Platform (VRP) and boasts various IDN features.


S5731-H24T4XC Specification

 

S5731-H24T4XC Specification

Fixed port

24 x 10/100/1000Base-T ports, 4 x   10GE     SFP+ ports

Dimensions   (H   x W x   D)

43.6 mm x 442 mm x 420mm

Chassis   height

1 U

Chassis   weight  

(including   packaging)

8.4 kg

Extended    slot

One extended slot, support 2 x     40GE, 

8   x 10GE Base-T, 2 x 25GE SFP28   or 8 x 10GE SFP+ cards

Power    supply  type
     
     

• 600 W AC (pluggable)

• 150 W AC (pluggable)

• 1000 W DC (pluggable)

Rated    voltage  range
     
     

• AC input (600 W AC ): 100 V   AC   to   240 V AC, 50/60 Hz

• AC input (150 W AC ): 100 V   AC   to   240 V AC, 50/60 Hz

• DC input (1000 W DC): -48   VDC   to   -60 V DC

Maximum    voltage range


     
     

• AC input (150 W AC ): 90 V     AC   to 264 V AC, 47 Hz to 63 Hz

• AC input (600 W AC ): 90 V     AC   to 290 V AC, 45 Hz to 65 Hz

• High-voltage DC input (600 W       AC): 190 V DC to 290 V DC 

(meeting 240 V high-voltage DC     certification)

• DC input (1000 W DC): -38.4     V   DC to -72V DC

Maximum     power consumption

114 W

Noise

• Under   normal temperature     (sound power): 57.5dB (A)

• Under high temperature   (sound     power): 70.9dB (A)

• Under normal temperature   (sound     pressure): 47.5dB (A)

Operating    temperature

• 0-1800 m altitude: -5°C to     45°C

• 1800-5000 m altitude:     The   operating temperature reduces 

   by 1ºC every time the   altitude   increases   by 220 m.

Storage     temperature

-40°C to +70°C

Relative     humidity

5% to 95% (non-condensing)

Surge     protection specification

(service port)

Common mode: ±6 kV

Surge    protection specification

 (power port)

 

• AC power port: ±6 kV in       differential mode, ±6 kV in common mode

• DC power port: ±2 kV in       differential mode, ±4 kV in common mode

Heat     dissipation

Air cooling heat dissipation,     intelligent   speed adjustment, and pluggable fans

Service     Features

MAC   address    table

IEEE 802.1d standards compliance

288K MAC address entries

MAC address learning and aging

Static, dynamic, and blackhole MAC       address entries

Packet filtering based on source   MAC     addresses

VLAN

4094 VLANs

Guest VLAN and voice VLAN

GVRP

MUX VLAN

VLAN assignment based on MAC       addresses, protocols, IP subnets, policies, 

and ports

VLAN mapping

Wireless     service

AP access control, AP domain       management, 

and AP   configuration template management

Radio management, unified static   configuration, 

and dynamic centralized management

WLAN basic services, QoS, security, and   user management

CAPWAP, tag/terminal location, and   spectrum   analysis

Ethernet    loop  protection

 

RRPP ring topology and RRPP       multi-instance

Smart Link tree topology and Smart       Link multi-instance, 

providing millisecond-level protection

switching

SEP

ERPS (G.8032)

BFD for OSPF, BFD for IS-IS, BFD     for   VRRP, and BFD for PIM

STP (IEEE 802.1d), RSTP (IEEE     802.1w),   and MSTP (IEEE 802.1s)

BPDU protection, root protection,     and   loop protection

MPLS

MPLS L3VPN

MPLS L2VPN (VPWS/VPLS)

MPLS-TE

MPLS QoS

IP routing

Static routes, RIP v1/2, RIPng,     OSPF,   OSPFv3, IS-IS, IS-ISv6, BGP, 

BGP4+, ECMP, 

routing policy

Up to 512K FIBv4 entries

Up to 64K FIBv6 entries

Interoperability

VLAN-Based Spanning Tree (VBST),     working   with PVST, PVST+, and RPVST

Link-type Negotiation Protocol   (LNP),     similar to DTP

VLAN Central Management Protocol     (VCMP),   similar to VTP

IPv6    features

Up to 64K ND entries

PMTU

IPv6 Ping, IPv6 Tracert, and IPv6       Telnet

ACLs based on   source IPv6   addresses,   destination IPv6 addresses, 

Layer 4   ports,  or protocol   types

Multicast Listener Discovery     snooping   (MLDv1/v2)

IPv6 addresses configured for       sub-interfaces, VRRP6, DHCPv6, and L3VPN

Multicast

IGMP v1/v2/v3 snooping and IGMP   fast     leave

Multicast forwarding in a VLAN and       multicast replication between VLANs

Multicast load balancing among   member     ports of a trunk

Controllable multicast

Port-based multicast traffic     statistics

IGMP v1/v2/v3, PIM-SM, PIM-DM, and       PIM-SSM

MSDP

MVPN

QoS/ACL

Rate limiting in the inbound and       outbound directions of a port

Packet redirection

Port-based traffic policing and       two-rate three-color CAR

Eight queues per port

DRR, SP and DRR+SP queue scheduling       algorithms

WRED

Re-marking of the 802.1p and DSCP       fields of packets

Packet filtering at Layer 2 to     Layer   4, filtering out invalid frames based on 

the source   MAC address, destination  

MAC address, source IP address, destination IP address, TCP/UDP port number ,   

protocol type, and VLAN   ID

Queue-based rate limiting and     shaping   on ports

Security

Hierarchical user management and       password protection

DoS attack defense, ARP attack       defense, and ICMP attack defense

Binding of the IP address, MAC       address, port number, and VLAN ID

Port isolation, port security, and       sticky MAC

MAC Forced Forwarding (MFF)

Blackhole MAC address entries

Limit on the number of learned MAC       addresses

IEEE 802.1x authentication and     limit   on the number of users on a port

AAA authentication, RADIUS     authentication,   and HWTACACS authentication

NAC

SSH V2.0

HTTPS

CPU protection

Blacklist and whitelist

Attack source tracing and     punishment   for IPv6 packets such as ND, DHCPv6, 

and MLD packets

Secure Boot

IPSec

MACSec-256

ECA

Deception

Reliability

LACP

E-trunk

Ethernet OAM (IEEE 802.3ah and IEEE       802.1ag)

ITU-Y.1731

DLDP

LLDP

BFD for BGP, BFD for IS-IS, BFD for     OSPF,   BFD for static route

VXLAN*

VXLAN L2 and L3 gateways

Centralized and distributed gateway

BGP-EVPN

Configured through the NETCONF     protocol

Super    Virtual  Fabric (SVF)

 

Working as an SVF Parent to     vertically   virtualize downlink switches 

and APs   as one device for management.

A two-layer client architecture is       supported.

IGMP snooping can be enabled on     access   switches (ASs)

and the maximum number of access     users on a port can be   configured.

ASs can be independently     configured. Services that are not supported 

by templates   can be configured on the   parent.

Third-party devices are allowed       between SVF parent and clients.

Working as an SVF client that is       plug-and-play with zero configuration

iPCA

Directly coloring service packets     to   collect real-time statistics on 

the   number of lost packets and   packet loss   ratio

Collection of statistics on the     number   of lost packets and packet loss 

ratio at   network and device   levels

TWAMP

Two-way IP link performance       measurement

Measurement on two-way packet     delay,   one-way packet loss rate, 

and one-way packet jitter

Management    and maintenance

iStack, with up to 9 member     switches   in a stack

SNMP v1/v2c/v3

RMON

Smart Application Control (SAC)

Web-based NMS

System logs and alarms of different       levels

GVRP

MUX VLAN

NetStream

Intelligent O&M

*CloudEngine S5731-H series     switches   require the VXLAN license or N1 advanced software package   to 

  

  support the  VXLAN   feature.

 

Product Details

Figure 1 shows the front panel of S5731-H24T4XC.

download.png

 

1

Twenty-four 10/100/1000BASE-T ports

2

Four 10GE SFP+ ports

Applicable modules and cables:

·           GE optical module

·           GE-CWDM optical        module

·           GE-DWDM optical        module

·           GE copper module        

            (100M/1000M   auto-sensing)

·           10GE SFP+ optical    module  

            (OSXD22N00 not supported)

·           10GE-CWDM optical      module

·           10GE-DWDM optical      module

·           1 m, 3 m, 5 m, and  10 m 

SFP+   high-speed copper cables

·           3 m and 10 m SFP+   AOC cables

·           0.5 m and 1.5 m SFP+ dedicated stack copper cables

·            (used for   zero-configuration stacking)

3

One console port

4

One ETH management port

5

One USB port

6

One PNP button

NOTICE:

To restore   the factory settings   and reset the switch,

hold down the button for at least     6 seconds.

To reset   the switch, press the   button.

Resetting the switch will cause service interruption. 

Exercise caution when you press   the PNP   button.

7

Ground screw

NOTE:

It is used   with a ground   cable.

8

Rear card slot

NOTE:

Applicable   card:

·           ES5D21X08T00

·           ES5D21Q02Q00

·           S7X08000 

(applicable in V200R019C10 and later   versions)

9

Fan module slot 1

NOTE:

Applicable   fan   module:

 FAN-023A-B Fan Module

10

Fan module slot 2

NOTE:

Applicable fan module: FAN-023A-B Fan Module

11

Power module slot 1

NOTE:

Applicable   power module:

·           600 W AC Power Module (PAC600S12-CB)

·           1000 W DC Power Module (PDC1000S12-DB)

·           150 W AC Power Module (PAC150S12-R)

·           180 W DC Power Module   (PDC180S12-CR) 

·           (applicable in V200R020C00 and later  versions)

12

Power module slot 2

NOTE:

Applicable   power module:

·           600 W AC Power Module (PAC600S12-CB)

·           1000 W DC Power Module (PDC1000S12-DB)

·           150 W AC Power Module (PAC150S12-R)

·           180 W DC Power        Module   (PDC180S12-CR)

·            (applicable in V200R020C00 and later  versions)

 

Applicable Modules

Table 2 shows the recommended modules.

 

Model

Description

PAC600S12-CB

600W AC Power Module(Back to Front, Power   panel side exhaust)

eSFP-GE-SX-MM850

Optical Transceiver,eSFP,GE,Multi-mode   Module(850nm,0.55km,LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver,eSFP,GE,Single-mode   Module(1550nm,40km,LC)

SFP-GE-LX-SM1310

Optical Transceiver,eSFP,GE,Single-mode   Module(1310nm,10km,LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver,eSFP,GE,Single-mode   Module(1310nm,40km,LC)

S-SFP-GE-LH80-SM1550

Optical Transceiver,eSFP,GE,Single-mode   Module(1550nm,80km,LC)

SFP-GE-ZBXU1

Optical   Transceiver,eSFP,GE,BiDi Single-mode   Module(1490nm(Tx)/1570nm(Rx),

80km,LC)

SFP-GE-LX-SM1490-BIDI

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1490/RX1310,10km,LC)

SFP-GE-ZBXD1

Optical   Transceiver,eSFP,GE,BIDI Single-mode   Module(1570nm(Tx)/1490nm(Rx),

80km,LC)

eSFP-GE-ZX100-SM1550

Optical Transceiver,eSFP,GE,Single-mode     Module(1550nm,100km,LC)

LE2MGSC40DE0

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1310/RX1490,40km,LC)

SFP-GE-LX-SM1310-BIDI

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1310/RX1490,10km,LC)

LE2MGSC40DE0

Optical Transceiver,eSFP,GE,BIDI   Single-mode   Module(TX1490/RX1310,40km,LC)

SFP-GE-BXU1-SC

1000Base,BIDI   Optical Transceiver,SFP,GE,Single-mode   Module(TX1490nm/RX1310nm,

10km,SC)

 

Get More Information

Do you have any question about the Huawei S5731-H24T4XC?

Contact us now via Live Chat or andy@ryderwell.com.



send inquiry to us

Related Product

Chat with us