S5731-H24P4XC

Huawei S5731-HSeries Switch S5731-H24P4XC with 24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 1*expansion slot, PoE+,without power module.


Description

S5731-H24P4XC  Overview


The CloudEngine S5731-H series switches are the next-generation intelligent gigabit 

fixed switches developed by Huawei. The CloudEngine S5731-H builds on Huawei's 

unified Versatile Routing Platform (VRP) and boasts various IDN features.


S5731-H24P4XC  Specification

S5731-H24P4XC Specification

Fixed port

24 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports

Dimensions (H   x W x D)

43.6 mm x 442 mm x 420mm

Chassis height

1 U

Chassis weight  (including   packaging)

8.6 kg

Extended slot

One extended slot, support 2 x 40GE, 8   x 10GE Base-T, 

2 x 25GE SFP28 or 8 x 10GE SFP+ cards

Power supply   type
 
 

1000 W PoE AC (pluggable)

Rated voltage   range
 
 

AC input (1000 W AC PoE): 100 V AC to   240 V AC, 

50/60 Hz

Maximum   voltage range

• AC input (1000 W AC PoE): 90 V   AC to 290 V AC, 45 Hz to 65 Hz

• High-voltage DC input (1000 W   AC PoE): 190 V DC to 290 V DC

(meeting 240 V high-voltage DC   certification)

Maximum   power consumption

• 121 W (without PD)

• 977 W (with PD, PD power   consumption of 720 W)

Noise

• Under normal temperature   (sound power): 62.3dB (A)

• Under high temperature (sound   power): 71.8dB (A)

• Under normal temperature (sound   pressure): 52.8dB (A)

Operating   temperature

• 0-1800 m altitude: -5°C to 45°C

• 1800-5000 m altitude: The operating temperature reduces 

by 1ºC every time the altitude increases   by 220 m.

Storage   temperature

-40°C to +70°C

Relative   humidity

5% to 95% (non-condensing)

Surge   protection specification(service port)

Common mode: ±6 kV

Surge   protection specification(power port)

• Differential mode: ±6 kV

• Common mode: ±6 kV

Heat   dissipation

Air cooling heat dissipation,   intelligent speed adjustment, 

and pluggable fans

Service   Features

MAC address   table

IEEE 802.1d standards compliance

288K MAC address entries

MAC address learning and aging

Static, dynamic, and blackhole MAC   address entries

Packet filtering based on source MAC   addresses

VLAN

4094 VLANs

Guest VLAN and voice VLAN

GVRP

MUX VLAN

VLAN assignment based on MAC   addresses, protocols, IP subnets, 

policies, and ports

VLAN mapping

Wireless   service

AP access control, AP domain   management, 

and AP configuration template management

Radio management, unified static   configuration, 

and dynamic centralized management

WLAN basic services, QoS, security,   and user management

CAPWAP, tag/terminal location, and   spectrum analysis

Ethernet loop   protection

 

RRPP ring topology and RRPP multi-instance

Smart Link tree topology and Smart   Link multi-instance, 

providing millisecond-level protection

switching

SEP

ERPS (G.8032)

BFD for OSPF, BFD for IS-IS, BFD for   VRRP, and BFD for PIM

STP (IEEE 802.1d), RSTP (IEEE 802.1w),   and MSTP  (IEEE 802.1s)

BPDU protection, root protection, and   loop protection

MPLS

MPLS L3VPN

MPLS L2VPN (VPWS/VPLS)

MPLS-TE

MPLS QoS

IP routing

Static routes, RIP v1/2, RIPng, OSPF,   OSPFv3, IS-IS, IS-ISv6, 

BGP, BGP4+, ECMP, routing policy

Up to 512K FIBv4 entries

Up to 64K FIBv6 entries

Interoperability

VLAN-Based Spanning Tree (VBST),   working with PVST, PVST+, 

and RPVST

Link-type Negotiation Protocol (LNP),   similar to DTP

VLAN Central Management Protocol   (VCMP), similar to VTP

IPv6 features

Up to 64K ND entries

PMTU

IPv6 Ping, IPv6 Tracert, and IPv6   Telnet

ACLs based on source IPv6 addresses,   destination IPv6 addresses, 

Layer 4 ports, or protocol types

Multicast Listener Discovery snooping   (MLDv1/v2)

IPv6 addresses configured for   sub-interfaces, VRRP6, DHCPv6, 

and L3VPN

Multicast

IGMP v1/v2/v3 snooping and IGMP fast   leave

Multicast forwarding in a VLAN and   multicast replication 

between VLANs

Multicast load balancing among member   ports of a trunk

Controllable multicast

Port-based multicast traffic   statistics

IGMP v1/v2/v3, PIM-SM, PIM-DM, and   PIM-SSM

MSDP

MVPN

QoS/ACL

Rate limiting in the inbound and   outbound directions of a port

Packet redirection

Port-based traffic policing and   two-rate three-color CAR

Eight queues per port

DRR, SP and DRR+SP queue scheduling   algorithms

WRED

Re-marking of the 802.1p and DSCP   fields of packets

Packet filtering at Layer 2 to Layer   4, 

filtering out invalid frames based on the source MAC address,

destination MAC address, source IP   address, destination IP address, 

TCP/UDP port number,

 protocol type, and VLAN ID

Queue-based rate limiting and shaping on   ports

Security

Hierarchical user management and   password protection

DoS attack defense, ARP attack   defense, and ICMP attack defense

Binding of the IP address, MAC   address, port number, and VLAN ID

Port isolation, port security, and   sticky MAC

MAC Forced Forwarding (MFF)

Blackhole MAC address entries

Limit on the number of learned MAC   addresses

IEEE 802.1 x  authentication and limit on  the  number  of users  on  a  port

AAA authentication, RADIUS   authentication, 

and HWTACACS authentication

NAC

SSH V2.0

HTTPS

CPU protection

Blacklist and whitelist

Attack source tracing and punishment   for IPv6 packets such as ND, 

DHCPv6, and MLD packets

Secure Boot

IPSec

MACSec-256

ECA

Deception

Reliability

LACP

E-trunk

Ethernet OAM (IEEE 802.3ah and IEEE   802.1ag)

ITU-Y.1731

DLDP

LLDP

BFD for BGP, BFD for IS-IS, BFD for   OSPF, BFD for static route

VXLAN*

VXLAN L2 and L3 gateways

Centralized and distributed gateway

BGP-EVPN

Configured through the NETCONF   protocol

Super Virtual   Fabric

(SVF)

 

Working as an SVF Parent to vertically virtualize downlink switches

and APs as one device for management.

A two-layer client architecture is   supported.

IGMP snooping can be enabled on access   switches (ASs) 

and the maximum number of

access users on a port can be   configured.

ASs can be independently configured.   

Services that are not supported by templates can be configured 

on the parent.

Third-party devices are allowed between SVF parent and clients.

Working as an SVF client that is plug-and-play with zero configuration

iPCA

Directly coloring service packets to collect real-time statistics 

on the number of lost packets

and packet loss ratio

Collection of statistics on the number of lost packets 

and packet loss ratio at network

and device levels

TWAMP

Two-way IP link performance   measurement

Measurement on two-way packet delay, 

one-way packet loss rate, and one-way packet jitter

Management   and maintenance

iStack, with up to 9 member switches   in a stack

SNMP v1/v2c/v3

RMON

Smart Application Control (SAC)

Web-based NMS

System logs and alarms of different   levels

GVRP

MUX VLAN

NetStream

Intelligent O&M

CloudEngine S5731-H series switches   require the VXLAN license or N1 advanced software package to support the

 VXLAN feature.

 

Product Details

Figure 1 shows the front panel of S5731-H24P4XC .

download.png

 

1

Twenty-four PoE+ 10/100/1000BASE-T ports

2

Four 10GE SFP+ ports

Applicable modules and cables:

·       GE optical   module

·       GE-CWDM   optical module

·       GE-DWDM   optical module

·       GE copper module  

        (100M/1000M auto-sensing)

·       10GE SFP+   optical module 

        (OSXD22N00 not supported)

·       10GE-CWDM   optical module

·       10GE-DWDM   optical module

·       1 m, 3 m, 5 m,   and 10 m SFP+

         high-speed copper cables

·        3 m and 10 m   SFP+ AOC cables

·        0.5 m and 1.5   m SFP+ 

         dedicated stack copper cables 

       (used for zero-configuration stacking)

3

One console port

4

One ETH management port

5

One USB port

6

One PNP button

NOTICE:

To restore the factory settings and reset the switch, 

hold   down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. 

Exercise caution when you press the PNP button.

7

Ground screw

NOTE:

It is   used with a ground cable.

8

Fan module slot 1

NOTE:

Applicable fan module: FAN-023A-B 

(Fan box(B,FAN panel side exhaust))

9

Fan module slot 2

NOTE:

Applicable fan module:

 FAN-023A-B (Fan box

(B,FAN panel side exhaust))

10

Power module slot 1

NOTE:

Applicable power module:

·      PAC1000S56-CB      

 (02312KND: 1000 W PoE AC Power Module)

·       PAC1000S56-CB 

 (02312KND-001: 1000 W PoE AC Power Module)

·      PAC1000S56-DB 

  (1000 W PoE AC Power Module) 

  (applicable in V200R020C10 and later versions)

·      PDC1000S56-CB 

(1000 W PoE DC Power Module) 

 (applicable  in V200R021C00 and later 

  versions)

·      PAC600S56-CB 

    600 W AC&240 V DC Power Module   

   (Back to Front, Power panel side exhaust) 

   (applicable in   V200R021C10 and later 

    versions)

11

Power module slot 2

NOTE:

Applicable power module:

      ·           PAC1000S56-CB   

(02312KND: 1000 W PoE AC Power Module)

·           PAC1000S56-CB 

(02312KND-001: 1000 W PoE AC Power   Module)

·           PAC1000S56-DB 

(1000 W PoE AC Power Module) 

(applicable   in V200R020C10 and later versions)

·           PDC1000S56-CB 

(1000 W PoE DC Power Module) 

(applicable   in V200R021C00 and later versions)

·           PAC600S56-CB 

(600 W AC&240 V DC Power Module   

(Back to Front, Power panel side exhaust)) 

(applicable in   V200R021C10 and later versions)

-

-

 

Applicable Modules

Table 3 shows the recommended modules.

Model

Description

eSFP-GE-SX-MM850

Optical Transceiver,eSFP,GE,Multi-mode Module(850nm,0.55km,LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver,eSFP,GE,Single-mode Module(1550nm,40km,LC)

SFP-GE-LX-SM1310

Optical Transceiver,eSFP,GE,Single-mode Module(1310nm,10km,LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver,eSFP,GE,Single-mode Module(1310nm,40km,LC)

S-SFP-GE-LH80-SM1550

Optical Transceiver,eSFP,GE,Single-mode Module(1550nm,80km,LC)

SFP-GE-ZBXU1

Optical Transceiver,eSFP,GE,BiDi Single-mode  Module ( 1490nm(Tx ) / 1570nm (Rx) , 80km,LC)

SFP-GE-LX-SM1490-BIDI

Optical Transceiver,eSFP,GE,BIDI Single-mode   Module ( TX1490 / RX1310 , 10km,LC)

SFP-GE-ZBXD1

Optical Transceiver,eSFP,GE,BIDI Single-mode   Module(1570nm(Tx)/1490nm(Rx) , 80km,LC)

eSFP-GE-ZX100-SM1550

Optical Transceiver,eSFP,GE,Single-mode   Module(1550nm,100km,LC)

LE2MGSC40DE0

Optical Transceiver,eSFP,GE,BIDI Single-mode   Module(TX1310/RX1490,40km,LC)

SFP-GE-LX-SM1310-BIDI

Optical Transceiver,eSFP,GE,BIDI Single-mode   Module(TX1310/RX1490,10km,LC)

LE2MGSC40DE0

Optical Transceiver,eSFP,GE,BIDI Single-mode   Module(TX1490/RX1310,40km,LC)

SFP-GE-BXU1-SC

1000Base,BIDI Optical Transceiver,SFP,GE,Single-mode   Module

(TX1490nm/RX1310nm,10km,SC)

 

Get More Information