S6730-H28Y4C Overview
S6730-H28Y4C (28*25GE SFP28 ports, 4*100GE QSFP28 ports,
without power module)
S6730-H28Y4C Specification
Item | Specification |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 231.0 mm (1.72 in. x 17.40 in. x 9.09 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 115 mm × 545 mm × 360 mm (4.53 in. x 21.46 in. x 14.17 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 3.4 kg (7.5 lb) |
Weight with packaging [kg(lb)] | 4.65 kg (10.25 lb) |
Typical power consumption [W] | 186 W |
Typical heat dissipation [BTU/hour] | 634.65 BTU/hour |
Maximum power consumption [W] | 253 W |
Maximum heat dissipation [BTU/hour] | 863.26 BTU/hour |
MTBF [year] | 54.68 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 64.5 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 51.7 dB(A) |
Number of card slots | 0 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | Not supported |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F).When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F). |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] | · AC input: 100 V AC to 240 V AC; 50/60 Hz · High-voltage DC input: 240 V DC · DC input: –48 V DC to –60 V DC |
Input voltage range [V] | · AC input: 90–290 V AC; 45–65 Hz · High-voltage DC input: 190 V DC to 290 V DC · DC input: -38.4 V DC to -72 V DC |
Maximum input current [A] | The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications. |
Memory | 4 GB |
Flash memory | 2 GB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | - |
Power supply surge protection [kV] | · AC power module configured: ±6 kV in differential mode, ±6 kV in common mode · DC power module configured: ±2 kV in differential mode, ±4 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air flows in from the left side and front panel, and exhausts from the right side. |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |
Product Details
Figure 1 shows the appearance of S6730-H28Y4C .
1 | Power module slot 1 NOTE: Applicable power module: · PDC260S12-DL (260 W DC Power Module) (300 W AC Power Module) | 2 | Power module slot 1 NOTE: Applicable power module: · PDC260S12-DL (260 W DC Power Module) (300 W AC Power Module) |
3 | Twenty-eight 1GE/10GE/25GE SFP28 optical ports | 4 | Four 40GE/100GE QSFP28 optical portS |
5 | One console port | 6 | One ETH management port |
7 | One USB port | 8 | One PNP button NOTICE: To restore the factory settings and reset the switch , hold down the button for at least 6 seconds. To reset the switch , press the button . Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.
|
9 | Ground screw NOTE: The ground screw is on the left side of the chassis. |
Get More Information
Do you have any question about the Huawei S6730-H28Y4C ?
Contact us now via Live Chat or andy@ryderwell.com.